* Privacy Policy * 3 Things Every Homeowner Must Know Before Their Builders Warranty Expires * Air Quality * Asbestos * Biological Pollutants * Common Definitions * Conserve Energy * Constructed Wetlands * EMFs in the Home * Home Insurance Tips * Lead * Mold Information * Mold & Moisture * Plumbing * Private Wells * Radon * Roofing * Septic Systems * Termites * Water Quality * Building a Home * Energy Efficiency * Foundation Insulation * Historic Renovation * Log Homes * Rehabilitation * Stucco * Electrical Safety * Child Safety * Holiday Safety * Pool Safety * Safety Checklist * Senior Safety Tips * Wildlife * 3 Mistakes * Closing Process * Things to Look For * Prebuilt Homes * What Really Matters * Why Pay More? * Ten Tips |
PlumbingPlumbing may be defined as practice, materials, and fixtures used in the installation, maintenance, and alteration of all piping, fixtures, appliances, and appurtenances in connection with sanitary or storm drainage facilities, the venting system, and the public or private water supply systems. Plumbing does not include the trade of drilling water wells, installing water softening equipment, or the business of manufacturing or selling plumbing fixtures, appliances, equipment, or hardware. A plumbing system consists of three separate parts: an adequate potable water supply system, a safe, adequate drainage system and ample fixtures and equipment. Background Factors
Definitions
Pressure absorbing devices that eliminate water hammer. They should be installed as close as possible to the valves or faucet and at the end of long runs of pipe.
The unobstructed vertical distance through the free atmosphere between the outlet of a water pipe and the flood level rim of the receptacle into which it is discharging.
The unobstructed vertical distance through the free atmosphere between the lowest opening from any pipe or faucet supplying water to a tank, plumbing fixture, or other device and the flood level rim of the receptacle.
An air lock is a bubble of air which restricts the flow of water in a pipe.
The flow of water or other liquids, mixtures, or substances into the distributing pipes of a potable water supply from any source or sources other than the intended source. Back siphonage is one type of backflow.
The flowing back of used, contaminated, or polluted water from a plumbing fixture or vessel into a potable water supply due to a negative pressure in the pipe.
Any part of the piping system other than the main, riser, or stack.
A vent connecting one or more individual vents with a vent stack.
The part of the lowest piping of a drainage system that receives the discharge from soil, waste, or other drainage pipes inside the walls of the building (house) and conveys it to the building sewer beginning 3 feet outside the building wall. Cross Connection Any physical connection or arrangement between two otherwise separate piping systems, one of which contains potable water and the other either water of unknown or questionable safety or steam, gas, or chemical whereby there may be a flow from one system to the other, the direction of flow depending on the pressure differential between the two systems. (See Backflow and Back siphonage.)
An area containing a series of one or more trenches lined with coarse aggregate and conveying the effluent from the septic tank through vitrified clay Pine or perforated, non-metallic pipe, laid in such a manner that the flow will be distributed with reasonable uniformity into natural soil. Drain Any pipe that carries waste water or water-borne waste in a building (house) drainage system. Flood Level Rim The top edge of a receptacle from which water overflows. Flushometer Valve A device that discharges a predetermined quantity of water to fixtures for flushing purposes and is closed by direct water pressures. Flush Valve A device located at the bottom of the tank for flushing water closets and similar fixtures. Grease Trap See Interceptor Hot Water Potable water that is heated to at least 120F and used for cooking, cleaning, washing dishes, and bathing. Insanitary Contrary to sanitary principles injurious to health. Interceptor A device designed and installed so as to separate and retain deleterious, hazardous, or undesirable matter from normal wastes and permit normal sewage or liquid wastes to discharge into the drainage system by gravity. Leader An exterior drainage pipe for conveying storm water from roof or gutter drains to the building storm drain, combined building sewer, or other means of disposal. Main Vent The principal artery of the venting system, to which vent branches may be connected. Main Sewer See Public Sewer. Pneumatic The word pertains to devices making use of compressed air as in pressure tanks boosted by pumps. Potable Water Water having no impurities present in amounts sufficient to cause disease or harmful physiological effects and conforming in its bacteriological and chemical quality to the requirements of the Public Health Service drinking water standards or meeting the regulations of the public health authority having jurisdiction. P & T (Pressure and Temperature) Relief Valve A safety valve installed on a hot water storage tank to limit temperature and pressure of the water. P Trap A trap with a vertical inlet and a horizontal outlet. Public Sewer A common sewer directly controlled by public authority. Relief Vent An auxiliary vent that permits additional circulation of air in or between drainage and vent systems. Septic Tank A watertight receptacle that receives the discharge of a building's sanitary drain system or part thereof and is designed and constructed so as to separate solid from the liquid, digest organic matter through a period of detention, and allow the liquids to discharge into the soil outside of the tank through a system of open-joint or perforated piping, or through a seepage pit. Sewerage System - A sewerage system comprises all piping, appurtenances, and treatment facilities used for the collection and disposal of sewage, except plumbing inside and in connection with buildings served and the building drain. Soil Pipe The pipe that directs the sewage of a house to the receiving sewer, building drain, or building sewer. Soil Stack The vertical piping that terminates in a roof vent and carries off the vapors of a plumbing system. Stack Vent An extension of a solid or waste stack above the highest horizontal drain connected to the stack. Sometimes called a waste vent or a soil vent. Storm Sewer A sewer used for conveying rain water, surface water, condensate. cooling water, or similar liquid waste. Trap A trap is a fitting or device that provides a liquid seal to prevent the emission of sewer gases without materially affecting the flow of sewage or waste water through it. Vacuum Breaker A device to prevent backflow (back siphonage) by means of an opening through which air may be drawn to relieve negative pressure (vacuum). Vent Stack The vertical vent pipe installed to provide air circulation to and from the drainage system and that extends through one or more stories. Water Hammer The loud thump of water in a pipe when a valve or faucet is suddenly closed. Water Service Pipe The pipe from the water main or other sources of potable water supply to the water-distributing system of the building served. Water Supply System The water supply system consists of the water service pipe, the water-distributing pipes, the necessary connecting pipes, fittings, control valves, and all appurtenances in or adjacent to the building or premises. Wet Vent A vent that receives the discharge of waste other than from water closets. Yoke Vent A pipe connecting upward from a soil or waste stack to a vent stack for the purpose of preventing pressure changes in the stacks. Main Features of an Indoor Plumbing System
Elements of a Plumbing System
The fixture risers start at the basement main and rise vertically to the fixtures on the upper floors. In a one-family dwelling, riser branches will usually proceed from the main riser to each fixture grouping. In any event the fixture risers should not depend on the branch risers for support but should be supported with a pipe bracket. Each fixture is then connected to the branch riser by a separate line. The last fixture on a line is usually connected directly to the branch riser. Hot Water Heaters: Hot water heaters are usually powered by electricity, fuel oil, gas, or in rare cases, coal or wood. They consist of a space for heating the water and a storage tank for providing hot water over a limited period of time. All hot water heaters should be fitted with a temperature-pressure relief valve no matter what fuel is used. This valve will operate when either the temperature or the pressure becomes too high due to an interruption of the water supply or a faulty thermostat. Pipe Sizes: The size of basement mains and risers depends on the number of fixtures supplied. However, a 3/4 inch pipe is usually the minimum size used. This allows for deposits on the pipe due to hardness in the water and will usually give satisfactory volume and pressure. Drainage SystemThe water supply brought into the house and used is discharged through the drainage system. This system is either a sanitary drainage system carrying just interior waste water or a combined system carrying interior waste and roof runoff. Sanitary Drainage System:The proper sizing of the sanitary drain or house drain depends on the number of fixtures it serves. The usual minimum size is 6 inches in dial diameter. The materials used are usually cast iron, vitrified clay, plastic, and in rare cases, lead. For proper flow in the drain the pipe should be sized so that it flows approximately one-half full. This ensures proper scouring action so that the solids contained in the waste will not be deposited in the pipe.
All branch drains must join the house drain with a "Y" -type fitting. The same is true for fixture drains joining branch drains. The "Y" fitting is used to eliminate, as much as possible, the deposit of solids in or near the connection. A build-up of these solids will cause a blockage in the drain.
The purpose of a trap is to seal out sewer gases from the structure. Since a plumbing system is subject to wide variations in flow, and this flow originates in many different sections of the system, there is a wide variation in pressures in the waste lines. These pressure differences tend to destroy the water seal in the trap. To counteract this problem mechanical traps were introduced. It has been found, however, that the corrosive liquids flowing in the system corrode or jam these mechanical traps. It is for this reason that most plumbing codes prohibit mechanical traps. There are many manufacturers of traps, and all have varied the design somewhat. The "P" trap is usually found in lavatories, sinks, urinals, drinking fountains, showers, and other installations that do not discharge a great deal of water. The drum trap is another water seal-type trap. They are usually used in the 4x5-inch or 4x8-inch sizes. These traps have a greater sealing capacity than the "P" trap and pass large amounts of water quickly. Drum traps are commonly connected to bathtubs, foot baths, sitz baths, and modified shower baths. The "S" 1 and the 3h "S" trap should not be us in plumbing installations. They are almost impossible to ventilate properly, and the 3h "S" trap forms a perfect siphon. Any trap that depends on a moving part for its effectiveness is usually inadequate and has been prohibited by the local plumbing codes. These traps work, but their design usually results in their being higher priced than the "P" or drum traps. It should be remembered that traps are used only to prevent the escape of sewer gas into the structure. They do not compensate for pressure variations. Only proper venting will eliminate pressure problems. Ventilation A plumbing system is ventilated to prevent trap seal loss, material deterioration. and flow retardation. The seal in a plumbing trap may be lost due to siphonage (direct and indirect or momentum), back pressure, evaporation, capillary attraction, or wind effect. The first two named are probably the most common causes of loss. If a waste pipe is placed vertically after the fixture trap, as in an "S" trap, the waste water continues to flow after the fixture is emptied and clears the trap. This is caused by the pressure of air on the fixture water's being greater than the pressure of air in the waste pipe. The action of the water discharging into the waste pipe removes the air from that pipe and thereby causes a negative pressure in the waste line. In the case of indirect or momentum siphonage, the flow of water past the entrance to a fixture drain in the waste pipe removes air from the fixture drain. This reduces the air pressure in the fixture drain, and the entire assembly acts as an aspirator such as the physician uses to spray an infected throat. Back pressureThe flow of water in a soil pipe varies according to the fixtures being used. A lavatory gives a small flow and a water closet a large flow. Small flows tend to cling to the sides of the pipe, but large ones form a slug of waste as they drop. As this slug of water falls down the pipe the air in front of it becomes pressurized. As the pressure builds it seeks an escape point. This point is either a vent or a fixture outlet. If the vent is plugged or there is no vent, the only escape for this air is the fixture outlet. The air pressure forces the trap seal up the pipe into the fixture. If the pressure is great enough the seal is blown out of the fixture entirely. Figures 6-17 and 6-18 illustrate this type of problem. Vent pipe installation is similar to that of soil and waste pipe. The same fixture unit criteria are used. Vent pipes of less than 11 D4 inches in diameter should not be used. Vents smaller than this diameter tend to clog and do not perform their function.
Total drainage system Up to now we have talked about the drain, soil waste, and vent systems of a plumbing system separately. For a working system, however, they must all be connected. |